NetworX NX-8Control/CommunicatorInstallation ManualTable of ContentsGE InterlogixGladewater, Texas1-800-727-2339General Description...
Page 10PROGRAMMING EXAMPLE TO BE INSERTED HERE.
Page 11FEATURE SELECTION DATA: Feature selection data will display the current condition (on or off) of eight featuresassociated with the programming
Page 12Segment 2- Phone #1 Backup Control: Programming a "0" in Segment 2 of this location will cause the NX-8 to makethe designated number
Page 13Segment 2: 1 = Zone and Box Tamper and Tamper Restore.2 = Auxiliary Power Overcurrent, Ground Fault, and Restore for both.3 = Wireless Sensor M
Page 14REPORTING EVENTS TO PHONE NUMBER 2Phone #2 can be used to back up Phone #1 or for a second receiver to multi-report or split report events. Pho
Page 15LOCATION 15 - DIAL ATTEMPTS/BACKUP CONTROL FOR PHONE #3 (2 segments, numerical data)Segment 1, Dial Attempts: Segment 1 of Location 15 is used
Page 16LOCATION 18 - CUSTOM COMMUNICATOR FORMAT (See locations 2, 8, &14)Segment 1: 1 = On for 1800hz transmit; Off for 1900hz.2= On for 2300hz ha
Page 17L LOCATION 23 - PARTITION 1, FEATURE AND REPORT SELECTIONS (3 segments, feature selection data)Location 23 is used to enable certain features t
Page 18DEFAULT ZONE TYPES (Configurations)Zones can be programmed to be one of twenty different zone types (configurations). Zone types # 17 - 20 can
Page 19NOTE: To “null” a zone, program the zone in “Partition Select” as zero (0) in all partitions and do notuse end-of-line resistors.L LOCATION 25
Page 2GENERAL DESCRIPTIONThe NetworX NX-8 represents a new approach to security systems design. Drawing on our experience in the worldmarket as the la
Page 20L LOCATION 31 - ZONES 25-32 ZONE TYPE GROUP (8 segments, numerical data)Location 31 contains the Zone Type for zones 25-32. Segment 1 is for zo
Page 21L LOCATION 37 - SIREN AND SYSTEM SUPERVISION (5 segments, feature selection data)Location 37 is used to enable various system feature and repor
Page 22L LOCATION 40 - SYSTEM TIMERS (10 segments, numerical data)Location 40 contains the duration of various system timing functions. Example: If yo
Page 23Location 44 contains the "Duress" code. This Location contains either 4 or 6 digits. If the 6-digit code option isenabled in Location
Page 24AUXILIARY OUTPUT EVENT SELECTIONDATA EVENT DATA EVENT0 /Burglary Alarm26Fire Trouble1 /Fire Alarm27Chime2 /24 Hour Alarm28 /Expander Trouble3 /
Page 25L LOCATION 51 - AUTOTEST CONTROL (4 segments, numerical data)Segment 1: Program a "1" if the interval is to be in hours; Program a &q
Page 26LOCATIONS 56- 83 ARE ONLY USED WHEN REPORTING EVENTS TO A PAGER OR USING A SLOW FORMATSUCH AS 4+2. WHEN USING CONTACT ID OR SIA, THERE IS NO NE
Page 27LOCATION 59 - TROUBLE COMMUNICATOR CODE, SLOW SPEED FORMATS ONLY (8 segments, numericaldata )Location 59 contains the event code for a zone &qu
Page 28LOCATION 65 - KEYPAD PANIC COMMUNICATOR CODE, SLOW SPEED FORMATS ONLY (2 segments,numerical data)Location 65 contains the tens and ones digits
Page 29LOCATION 74 - EXPANDER TROUBLE AND EXPANDER TROUBLE RESTORE COMMUNICATOR CODES,SLOW SPEED FORMATS ONLY (4 segments, numerical data)Location 74
Page 3FEATURE DEFINITIONSAbort- If enabled, the NX-8 will wait the programmed number of seconds in location 40 prior to sending an alarm.During this d
Page 30LOCATION 81 - START PROGRAM AND END PROGRAM COMMUNICATOR CODES, SLOW SPEED FORMATSONLY (4 segments, numerical data)Location 81 contains the ten
Page 31LOCATION 93 - PARTITION 3 FEATURE AND REPORTING SELECTIONS (3 segments, feature selection data)Location 93 is used to enable certain features t
Page 32LOCATION 101 - ACCOUNT CODE FOR PARTITION 6 (6 segments, numerical data)The account code sent when partition 6 is reported is programmed in loc
Page 33LOCATION 109 - PARTITION 8 ENTRY EXIT TIMERS (4 segments, numerical data)Location 109 is used to enter in seconds the Entry and Exit times. The
Page 34LOCATION 115 - ZONE TYPE 3 CHARACTERISTIC SELECT (3 segments, feature selection data)Use "Zone Type Characteristic Selections" descri
Page 35LOCATION 129 - ZONE TYPE 10 CHARACTERISTIC SELECT (3 segments, feature selection data)Use "Zone Type Characteristic Selections" descr
Page 36LOCATION 142 - ZONE TYPE 17 ALARM EVENT CODE (1 segment, numerical data)Location 142 contains the event code sent for a Contact ID or SIA repor
Page 37NX-8 PROGRAMMING WORKSHEETS(Factory defaults for segments are in bold italics text and "Quick Start" locations are identified with th
Page 38LOC PG DESCRIPTION DEFAULT PROGRAMMING DATAPHONE #2, SELECTING WHICH PARTITIONS REPORT TO PHONE #2Segment #1 (Circle Numbers To Program)11 1412
Page 39LOC PG DESCRIPTION DEFAULT PROGRAMMING DATAL19 16 DOWNLOAD ACCESS CODE8-4-8-0-0-0-0-0________L20 16 RINGS TO ANSWER DOWNLOAD8_DOWNLOAD CONTROLS
Page 4Cancel- If enabled, the NX-8 will send a "Cancel" report if when the system is disarmed and the [Cancel] button ispressed within 5 min
Page 40LOC PG DESCRIPTION DEFAULT PROGRAMMING DATAL27 19 ZONES 9-16, ZONE TYPES6-6-6-6-6-6-6-6________ZONES 9-16, PARTITION SELECTION (Segment 1=Zone
Page 41LOC PG DESCRIPTION DEFAULT PROGRAMMING DATAL35 20 ZONES 41-48, ZONE TYPES6-6-6-6-6-6-6-6________ZONES 41-48, PARTITION SELECTION (Segment 1=Zon
Page 42LOC PG DESCRIPTION DEFAULT DATASegment #5 (Circle numbers to program)L37 2112345678Lost Clock service LED enable.Zone Doubling enable.Disable o
Page 43LOC PG DESCRIPTION DEFAULT DATAGO TO PROGRAM CODE PARTITION AND AUTHORIZATIONSegment #1 (Circle numbers to program)12345678Reserved.Enables &qu
Page 44LOC PG DESCRIPTION DEFAULT DATAAUTOTEST CONTROLSegment #1:Program a "1" if the interval is hours, a "0" if in days.Add a A2
Page 45LOC PG DESCRIPTION DEFAULT DATABYPASS COMMUNICATOR CODE, SLOW SPEED FORMATS ONLYSegment #1: Partition #1 Bypass code 0 _Segment #2: Partition #
Page 46LOC PG DESCRIPTION DEFAULT DATACOMMUNICATOR CODES FOR SLOW SPEED FORMATS ONLY62 27 DURESS 0-0 __63 27 AUXILIARY 1 0-0 __64 27 AUXILIARY 2 0-0 _
Page 47LOC PG DESCRIPTION DEFAULT DATAPARTITION 2, FEATURE AND REPORTING SELECTIONSegment #1 Segment #2 Segment #390 3012345678Quick ArmRe-ExitAuto By
Page 48LOC PG DESCRIPTION DEFAULT DATAPARTITION 5, FEATURE AND REPORTING SELECTIONSegment #1 Segment #2 Segment #399 3112345678Quick ArmRe-ExitAuto By
Page 49LOC PG DESCRIPTION DEFAULT DATAPARTITION 8, FEATURE AND REPORTING SELECTIONSegment #1 Segment #2 Segment #3108 3212345678Quick ArmRe-ExitAuto B
Page 5Group Bypass- A designated group of zones can be programmed to bypass by pressing [Bypass]- [0]-[Bypass]-[Bypass] prior to arming. (See location
Page 50125 34 ZONE TYPE 8 CHARACTERISTIC SELECT 1-13-378126 34 ZONE TYPE 9 ALARM EVENT CODE 7 _127 34 ZONE TYPE 9 CHARACTERISTIC SELECT 6-1245-5678128
Page 51APPENDIX 1 REPORTING FIXED CODES IN CONTACT ID AND SIAThe table below list the event codes sent for the following reports (if enabled) when usi
Page 52APPENDIX 2 REPORTING ZONE CODES IN SIA OR CONTACT IDThe NX-8 has the ability to report SIA level 1 transmissions to either or both phone number
Page 53APPENDIX 3 EXPANDER NUMBERS FOR REPORTING EXPANDER TROUBLEThe tables below list the device numbers that will be reported for trouble conditions
Page 54NX-8 WIRING DIAGRAM For CE labeled products, please refer to page 57 for specific electrical requirements.
Page 55TERMINAL DESCRIPTIONTERMINAL DESCRIPTIONR1 House Telephone Ring (Grey).R Telephone Ring (Red).T Telephone Tip (Green).T1 House Telephone Tip (B
Page 56LOCAL TELEPHONE COMPANY INTERFACE INFORMATIONTELEPHONE CONNECTION REQUIREMENTSExcept for telephone company provided ringers, all connections to
Page 57NOTICES (Applies to products whichhave the CE mark attached)Declaration of Conformity Manufacturer’s Name: Caddx ControlsManufacturer’s Address
Page 58UNDERWRITERS LABORATORIES INFORMATIONThe NetworX NX-8 holds the following listings from Underwriters Laboratories (US and Canadian):Household B
Page 59BOARD INSTALLATION Inside the can, several 2-holed insertion points have beenconstructed. This allows for either vertical or horizontal placem
Page 6Siren Blast For Arming- The NX-8 can be programmed to give a one second siren blast when the panel is armed, atthe end of the exit delay, or whe
Page 60SYSTEM NOTES
SPECIFICATIONSOPERATING POWER 16.5 VAC 25, 40, or 50 VA TransformerAUXILIARY POWERw/25 VA Transformer 12 VDC Regulated 500 mAw/40 or 50 VA Transformer
Page 7PROGRAMMING THE NX-8 LED KEYPADSThis section describes how to program the address and partition of each keypad as well as the options that areav
Page 8CHANGING USER CODES:1) Enter [r]-[5]-[master code] - The "Ready" LED will flash.2) Enter the 2 digit user number (always 2 digits such
Page 9PROGRAMMING THE NX-8 CONTROLENTERING THE PROGRAM MODE: To enter the Program Mode, press [r]-[8]. At this time, the five function LEDs(Stay, Chim