LOC PG DESCRIPTION DEFAULT YOUR DATA
242 8 Seg 3 LED2 (RED) OPTIONS 1
1 = "On" follows system Armed status
2 = "On" to toggle with the Open Collector output
3 = "On" if inverted
4-8= Reserved.
Seg 4 READER PARTITION 1,2,3,4,5,6,7,8
1 = "On" if reader is in Partition 1
2 = "On" if reader is in Partition 2
3 = "On" if reader is in Partition 3
4 = "On" if reader is in Partition 4
5 = "On" if reader is in Partition 5
6 = "On" if reader is in Partition 6
7 = "On" if reader is in Partition 7
8 = "On" if reader is in Partition 8
243 9 PROGRAMMING THE ZONES
Seg 1 Door Shunt Zone 0 = Disabled
Seg 2 Request To Exit (RTE) 0 = Disabled
244 9 READER TIMES
Seg 1 Scan Time (1/100 seconds) 100 = 1 second
Seg 2 Relay Active Time (seconds) 10 = 10 seconds
Seg 3 Door Fault Warning Time (seconds) 30 = 30 seconds
Seg 4 Door Fault Alarm Time (seconds) 0 = Disabled
245 9 RESET THE READER ADDRESS
Entering a “0” will reset and cause the reader to cease
functioning.
246 10 PROGRAMMING THE ACCESS OPTIONS
Seg 1 DOOR OPTIONS
1 = "On" if locking mechanism is a Maglock or Drop Bolt.
2 = "On" if access is allowed regardless of Armed status of the system.
3 = "On" if the door is not to be latched unlocked during an open schedule.
4 = "On" if onboard open collector output only triggers during an open schedule.
5 = “On” if onboard open collector output only triggers during a close schedule.
6 = “On” if Forced Entry Alarm is logged.
7 = “On” if access allowed without an RTE.
8 = “On” if relay operates normally during off-schedule (
outside of regular operating hours).
Seg 2 SCHEDULES FOR ONBOARD OPEN COLLECTOR OUTPUT
1 = "On" if driver follows Schedule 1.
2 = "On" if driver follows Schedule 2.
3 = "On" if driver follows Schedule 3.
4 = "On" if driver follows Schedule 4.
5 = "On" if driver follows Schedule 5.
6 = "On" if driver follows Schedule 6.
7 = "On" if driver follows Schedule 7.
8 = "On" if driver follows Schedule 8.
Seg 3 MORE DOOR OPTIONS
1 = “On” if egress input is to be disabled.
2-8 = Reserved.
247 10 OPENING TIME FOR SCHEDULE 1
Seg 1 Hour of Opening Time (24-hr format) 8 = 8 AM
Seg 2 Minutes after Hour of Opening 0
248 10 CLOSING TIME FOR SCHEDULE 1
Seg 1 Hour of Closing Time (24-hr format) 20 = 8 PM
Seg 2 Minutes after Hour of Closing 0
249 10 DAYS FOR SCHEDULE 1
1 = "On" if schedule is active on Sunday.
2 = "On" if schedule is active on Monday.
3 = "On" if schedule is active on Tuesday.
4 = "On" if schedule is active on Wednesday.
5 = “On” if schedule is active on Thursday.
6 = “On” if schedule is active on Friday.
7 = “On” if schedule is active on Saturday.
8 = “On” if schedule is disabled on holidays.
250 10 OPENING TIME FOR SCHEDULE 2
Seg 1 Hour of Opening Time (24-hr format) 8 = 8 AM
Seg 2 Minutes after Hour of Opening 0
251 10 CLOSING TIME FOR SCHEDULE 2
Seg 1 Hour of Closing Time (24-hr format) 20 = 8 PM
Seg 2 Minutes after Hour of Closing 0