EXITING THE PROGRAM MODE
When all the desired changes in programming have been made, it is time to exit the
program mode. Press the [Exit] key to exit this programming level, and go to the “Select a
Module To Program” level. If no additional modules are to be programmed, press the
[Exit] key again to exit the program mode. If there is a module to be programmed, you
can select it by entering its address, followed by the [#] key (see “Selecting the Module To
Program” above). The procedure for programming these devices is the same as for the
control panel, except that the locations will be for the module selected.
Note: the timeout for the program mode is 15 minutes.
PROGRAMMING DATA
There are only two possible types of programming data. One type of data is numerical:
data of this type can assume values from 0 -15 or 0 -255, depending on the location's
segment. The other type is feature selection data: this data is used to turn features on or
off. Use the following procedures when working with these two data types:
Numerical data: entering a number from 0-255 on the numeric keys of the system
keypad programs numerical data. To view the data in a location, a binary process is used.
With this process, the LED’s for zones 1 through 8 are utilized, and the numeric
equivalents of their illuminated LED’s are added together to determine the data in a
programming location. The numeric equivalents of these LED’s are as follows:
Zone 1 LED = 1 Zone 2 LED = 2 Zone 3 LED = 4 Zone 4 LED = 8
Zone 5 LED = 16 Zone 6 LED = 32 Zone 7 LED = 64 Zone 8 LED = 128
Example: If the numerical data to be programmed in a location is “66”, press [6]-[6] on
the keypad. The LED’s for zone 2 and zone 7 will light up, showing that 66 is in this
location (2 + 64 = 66). See the example p. 26.
Once the data has been programmed, press the [*] key to enter the data, and advance to
the next segment of that location. After the last segment of a location has been
programmed, press the [*] key to exit from that location - this turns the “Ready” LED off
and the “Armed” LED on. As before, you are now ready to enter another programming
location. If you try to program a number that is too large for a particular segment, the
keypad sounder will emit a triple beep to indicate an error, and will remain in that segment
awaiting a valid entry. Remark: On the LCD keypad, the number in the location will be
displayed. For locations with a maximum of 15, the hexadecimal equivalent will be
displayed in parenthesis. Example: 11 (B) or 14 (E).
Feature selection data: feature selection data will display the current condition (on or
off) of eight features associated with the selected programming location and segment. If
you press a button on the keypad (1 to 8) that corresponds to the “feature number” within
a segment, this will toggle the feature (on/off). By pressing any numeric key between [1]
and [8] to select a feature, you will make the corresponding LED light up (feature ON).
Press the number again, and the LED will go out (feature OFF). You will see that
numerous features can be selected from within one segment. For instance, if you want all
eight features of a segment, pressing [1]-[2]-[3]-[4]-[5]-[6]-[7]-[8] will turn on LED's 1 to 8
as you press the keys, indicating that those features are enabled. After you have selected
the setting of the features for this segment, press the [*] key. This will enter the data and
advance automatically to the next segment of the location. When you are in the last
segment of a location and you press the [*] key to enter the data, you will exit from that
location as well. This will turn off the “Ready” LED, and will turn on the “Armed” LED. As
before, you are now ready to enter another programming location.