Auxiliary power overcurrent
The NX-6 will light up the “Service” LED on the keypad whenever too much current is
being drawn from any device powered by the system. This condition can be reported to
the central station (see location 37 segment 3).
A+B alarm reporting (Sweden)
When this feature is enabled, a first trigger from a zone will send a BG report
(unverified alarm or B-alarm) for that zone. The B-alarm message will be written in the
log. In addition, a fix 30 minutes timer will start. If a zone is triggered for a 2nd time
within the 30 minutes time frame, this zone will send a BA report (burglary alarm or
verified alarm) to the monitoring station. If there is no 2nd zone that was triggered within
30 minutes, the timer will be cleared. A+B alarm reporting only works with intrusion zone
types using the SIA formats. When this feature is enabled, the standard cross-zoning
feature will be in-active (see location 37 segment 3).
Box tamper
The NX-6 has an input for a normally closed tamper switch (see wiring diagram). The box
tamper can be programmed to report, and/or sound the siren and/or the keypad. These
terminals can be enabled or disabled by programming (see locations 37 segment 2 and 3,
and location 39).
Built In siren driver
The NX-6 has a built-in 112 dB siren driver. If desired, this built-in driver can easily be
converted to a 1 amp voltage output by programming (see location 37 segment 2).
Bypass toggle
This feature will enable the end user to toggle (turn on or off) the bypass of an interior
zone while the system is armed. This is done by pressing the [Bypass] key (see location
23 segment 2).
Call back
When this feature is enabled, the control panel will use the call back phone number to call
the download computer before it begins a download (see locations 21 and 22).
Cancel
If this feature is enabled, the NX-6 will send a “Cancel” report when the system is
disarmed and the [Cancel] button is pressed within 5 minutes of an alarm. Once the
[Cancel] key has been pressed, the “Cancel” LED will light up until the central station
acknowledges the “Cancel” report (see location 23 segment 3).
Chime
This feature can be turned on and off using the “chime” key. When the system is in the
disarmed state, a trip on selected zones will generate either a DING-DONG or a single
tone through the keypad sounder (depending on the keypad programming). This lowest
level of security can be enabled by zone; this is done by programming the appropriate
zone configuration for it, or by customizing its zone configuration (see locations 111-169).
Code required options
The NX-6 can be programmed to require a code in order to bypass zones and/or to
initiate a download using the [*]-[9]-[8] or [*]-[9]-[9] function (see locations 23 segment 2
and 41).
Communication formats
The NX-6 can report in multiple formats. You are recommended to use Contact ID or SIA
formats if possible. If you wish to report to a private phone (using the voice module) or to
a central station in a 4+2 format, you must program each code that is to be reported (see
locations 56-83 and 111-169).
NX-6-EUR Installation manual Page 7 23/12/04